- With or without metal hose
- For low and high viscosity fluids
To atomize low and high viscosity fluids (max. viscosity 420 mm²/s). The spraying angle on this atomizer is 90° in reference to air and fluid connection.
Operating pressure 2 - 6 bar. The higher the pressure, the finer the mist.
How it works:
The fluid hose is either laid into a pressure-free tank or connected. The atomizer should always be fixed a little above the maximum fluid level in the tank. With compressed air applied, the fluid is carried along well-metered by the air rushing through (a built-in check valve in the fluid hose prevents the medium from dropping too fast).
The fast response times allow ultra short clock cycles. The atomizer can be actuated either permanently or on a cycle base by a control unit (e.g. BA) but always in well-metered quantities. The fluid is properly and economically fed into the centre of the air stream. With the air and fluid choke (see picture) the amount of air and fluid is finely adjustable.
Tank, hoses, and other accessories are available under Accessories.
|