B L O W  U N I T  -  
V A R I A B L E   O S C I L L A T O R   F O R   R O B U S T   A P P L I C A T I O N S  –  S E R I E S   B A

- Setting the pace

Compressed air should be available in the right moment and at the precise point, e.g. for tools on punches and presses. Each punching or pressing movement generates foreign particles that have to be removed from the tool.

How it works:
Indepent of the machine, one can set pause and pulse times between 0.1 and 10 seconds. The pause time (delay) can be set with the upper control, the pulse time (blast time) with the lower control.
That way the compressed air is used in a controlled and economical manner. The toggle switches left of the controls allow to select a time frame between 1 s and 10 s or between 0.1 s and 1 s for the fine adjustment. The automatic blow unit has a proprietary clock generator (= automatic). However, you can also request the machine cycle rate via an inductive switch which can be connected externally on the bottom of the housing (suitable inductive switch + cable – see table).
The pressure valve with its large 3/8“ aperture allows a strong air blast.
Order code incl. valve: BA/01.

1) Pause (delay) controller
2) Impulse (blow time) controller
3) Switch for impulse automatic or external impulse
4) Connection for inductive switch
Order-No. IN12x1-S1 + cable K12S+B-200 - refer to the chart
5) Optional valve - refer to the chart
6) Overall depth incl. mounting bracket: 172 mm






Order-No.
Without
magnetic valve
With
magnetic valve*
BA x -
BA/01 - 2/2 way 3/8"
BA/04 - 3/2 way 1/8"
IN12-S1 Inductive switch M12x1,
switching distance 2.0 mm,
length 45 mm, closer
K12S+B-200 Connection cable 2 m + plug with socket